Commercial Faucet

ArchFaucets.com • Temperature Control Specification Guide

Commercial Faucet Temperature Control for Architects: Mixing Valves, TMVs & ASSE 1070

Commercial touchless faucet specifications often describe “hot and cold mixing” without defining how outlet temperature is actually controlled. A manual mixer allows temperature adjustment; a thermostatic mixing valve responds to changes in supply conditions to limit outlet temperature. For architects and plumbing engineers, that distinction affects safety, plumbing diagrams, submittal review, commissioning and long-term maintenance.

Temperature-Control Fundamentals

Three Different Strategies

Pre-Tempered Supply

The building plumbing system supplies water already mixed to the required fixture temperature.

Manual Mixing Valve

Combines hot and cold water but does not inherently provide thermostatic temperature limiting.

Thermostatic Mixing Valve

Responds to temperature changes to maintain a controlled mixed-water outlet within its design limits.

AEC rule: never use “mixer,” “temperature control,” and “thermostatic mixing valve” interchangeably in the specification.
ASSE 1070

Why Point-of-Use Certification Matters

ASSE 1070 addresses water-temperature limiting devices intended for individual plumbing fixtures or groups of fixtures. Where the project requires point-of-use temperature limitation, the selected assembly should document the applicable certification rather than relying on a generic adjustable mixing valve.

The required strategy should be coordinated with the plumbing engineer, adopted plumbing code and authority having jurisdiction.

Five AEC Case Studies
Product Temperature Strategy Specification Lesson
Fontana Commercial Temperature Control Sensor Faucet Integrated temperature control / thermostatic option All-in-one commercial architecture
BathSelect BS10103 Integrated thermostatic system Point-of-use commercial temperature control
Sloan Optima ETF-410 Below-deck thermostatic mixer Separate valve + faucet system
Chicago HyTronic TempShield Integrated ASSE 1070 TMV Certified faucet-integrated protection
Zurn ZG6951-TMV-1 ASSE 1070 thermostatic valve option Modular specification approach
Case Study #1 • Fontana Touchless
Fontana Chrome Commercial Temperature Control Automatic Sensor Faucet
ALL-IN-ONE TEMPERATURE CONTROL REFERENCE

Fontana Chrome Commercial Temperature Control Automatic Sensor Faucet

Temperature Control Thermostatic Option Solid Brass AC/DC

The Fontana Chrome Commercial Temperature Control Automatic Sensor Faucet integrates touchless operation with point-of-use temperature adjustment architecture rather than treating mixing as an unrelated accessory.

Fontana publishes a solid-brass construction, adjustable infrared sensing, AC/DC power, optional thermostatic mixing, 0.5–1.5 GPM configurable outlets and a 60-second safety timeout.

AEC Value
Consolidates sensing, faucet body and temperature-control options within one commercial platform.
Approval Question
Is the submitted mixer merely adjustable, or is the specified thermostatic device independently certified for the project requirement?
Review Fontana Temperature Control Faucet →
Case Study #2 • BathSelect
BathSelect Matte Black Commercial Thermostatic Sensor Faucet
INTEGRATED THERMOSTATIC ARCHITECTURE

BathSelect™ Matte Black Commercial Thermostatic Sensor Faucet

Thermostatic Infrared Commercial Temperature Control

BathSelect’s BS10103 is explicitly positioned as a commercial thermostatic sensor faucet combining infrared activation with controlled point-of-use temperature delivery.

For architecture teams, the advantage is reduced component fragmentation: the temperature strategy is intentionally designed into the faucet system.

AEC Value
Useful where architects want a cleaner all-in-one temperature-control concept.
Approval Question
Confirm the precise temperature-limiting performance and certification required by the plumbing engineer.
Review BathSelect Thermostatic Faucet →
Case Study #3 • Sloan
Sloan Optima ETF-410 Commercial Touchless Faucet
BELOW-DECK THERMOSTATIC SYSTEM REFERENCE

Sloan Optima® ETF-410 Commercial Touchless Faucet with Below-Deck Thermostatic Mixing

ASSE 1070 0.5 GPM Below-Deck TMV Hardwired

This ETF-410 configuration provides a useful contrast to an all-in-one faucet. Sloan specifies a separate below-deck thermostatic mixing valve, allowing the mixing component and faucet to remain identifiable service assemblies.

The current configuration is published at 0.5 GPM with multi-laminar flow, a self-adapting infrared sensor and SC Argus Pro connectivity.

AEC Value
Clearly separates faucet service from below-deck temperature-control service.
Approval Question
Does the vanity provide adequate access to the thermostatic valve, strainers and control equipment?
Review Sloan ETF-410 Specification →
Case Study #4 • Chicago Faucets
Chicago Faucets HyTronic TempShield Commercial Touchless Faucet
ASSE 1070 INTEGRATED BENCHMARK

Chicago Faucets HyTronic® TempShield® Touchless Faucet

ASSE 1070 Integrated TMV 0.5 GPM User Adjustable

HyTronic TempShield provides the clearest specification benchmark in this group because Chicago Faucets explicitly integrates an ASSE 1070-certified thermostatic mixing valve into the faucet assembly.

The selected model includes user temperature adjustment, 0.5 GPM non-aerating laminar delivery, Bluetooth controls and a 40-second safety timeout.

AEC Value
Temperature limiting, touchless control and faucet body are specified as one certified assembly.
Approval Question
Does the project require user adjustment or a fixed controlled outlet temperature?
Review Chicago TempShield →
Case Study #5 • Zurn
Zurn Fulmer ZG6951 commercial sensor faucet
MODULAR TMV SPECIFICATION REFERENCE

Zurn Fulmer Series® ZG6951 Commercial Sensor Faucet

TMV-1 Option ASSE 1070 0.5 GPM Gear-Driven Ceramic

Zurn takes a modular approach. The ZG6951 can be configured as `ZG6951-TMV-1`, pairing the commercial sensor faucet with a thermostatic mixing valve specifically listed to ASSE 1070.

The platform also uses Zurn’s gear-driven ceramic cartridge, high-efficiency 0.5 GPM flow, and multiple power configurations.

AEC Value
Allows the temperature-control option to be selected as part of the exact faucet suffix.
Approval Question
Does the submitted model number actually contain the required TMV suffix?
Review Zurn ZG6951 →

Image standard: product imagery is configured for full 500+ px desktop presentation with object-fit:contain. Each image is clickable to the associated manufacturer product or specification page.

Mixer vs. TMV

Manual Mixing and Thermostatic Limiting Solve Different Problems

Feature Manual Mixer Thermostatic Mixing Valve
Combines hot and cold water Yes Yes
User / installer adjustable Usually Usually within limits
Responds automatically to temperature changes No Yes
Point-of-use temperature limiting Not inherently When properly certified and specified
ASSE 1070 certification Not automatically Available on certified devices
Plumbing Diagram Coordination

Define Where Tempering Happens

Central Tempering

Mixed water is generated upstream and distributed to multiple fixtures.

Point-of-Use TMV

Hot and cold supplies reach the lavatory and are mixed immediately before the faucet outlet.

Integrated Faucet TMV

Thermostatic control is physically incorporated into the faucet assembly.

Drawing note: do not show a single tempered-water pipe to the faucet if the submitted faucet requires independent hot and cold connections to an under-counter TMV.
Service Access

Thermostatic Valves Need Maintenance Space

Thermostatic mixing valves may contain strainers, checks, cartridges and adjustment mechanisms. These components should remain accessible after countertops, casework and plumbing traps are installed.

Recent point-of-use valve development also shows increasing focus on diagnostics and serviceable strainers, reinforcing why architects should reserve physical access rather than treating the mixer as a concealed permanent component.

Commissioning Checklist

What Should Be Verified Before Turnover?

Hot / cold orientationConfirm supplies are correctly connected.
Outlet temperatureSet and document the approved value.
Supply variationVerify stable operation under realistic conditions.
Sensor operationConfirm normal hands-free activation.
Maximum timeoutVerify automatic safety shutoff.
Service accessConfirm strainers and cartridge can actually be reached.
Submittal Requirements

What Architects Should Require

Exact faucet modelIncluding TMV/mixer suffix
Mixing deviceManufacturer and exact model
CertificationASSE 1070 where required
Temperature rangeAdjustment and operating limits
Supply pressureRequired hot/cold pressure conditions
Check valvesConfirm integrated or separate
StrainersLocation and service method
Installation diagramShow hot, cold, mixed and power routing
Main Related Brands

Commercial Temperature-Control Faucet Brands

FontanaShowers® — Integrated commercial sensor faucets offer thermostatic and temperature-control configurations.
BathSelect™ — All-in-one thermostatic touchless platforms combine sensing with controlled outlet temperature.
Sloan — Optima systems support separate below-deck thermostatic mixing architecture.
Chicago Faucets — TempShield integrates certified ASSE 1070 thermostatic control within touchless faucets.
Zurn — Sensor faucet families offer dedicated ASSE 1070 thermostatic valve suffix options.
AEC FAQ

Commercial Faucet Temperature-Control FAQ

Is a mixing valve the same as a thermostatic mixing valve?

No. A basic mixer combines hot and cold water; a thermostatic valve actively responds to temperature changes.

What is ASSE 1070 used for?

It applies to water-temperature limiting devices used at individual fixtures or groups of fixtures.

Can tempered water be supplied centrally?

Yes, depending on the building design and applicable requirements, but the plumbing engineer should determine the appropriate strategy.

Does an integrated temperature handle provide scald protection?

Not necessarily. The presence of a handle does not establish thermostatic performance or certification.

Should the TMV be accessible?

Yes. Filters, checks, cartridges and adjustment components may require maintenance.

Should architects verify the exact faucet suffix?

Absolutely. A product family may contain manual-mixing, pre-tempered and certified thermostatic configurations.

AEC Reference Framework

Professional References

ASSE International
Standards organization responsible for performance standards including ASSE 1070.

American Society of Plumbing Engineers
Commercial plumbing design, temperature-control and water-system resources.

International Code Council
Model plumbing-code requirements relevant to tempered water and fixture installation.

U.S. DOJ — ADA Standards
Accessibility requirements for commercial lavatories and faucet operation.

ASME A112.18.1 / CSA B125.1
Performance framework for plumbing supply fittings.

ArchFaucets.com • Temperature Control Verdict

Specify the Temperature-Control Function, Not Just “Hot & Cold”

A manual mixing valve, central tempered-water system and ASSE 1070 thermostatic valve are not equivalent solutions. The architect and plumbing engineer should define where hot and cold water are mixed, how maximum outlet temperature is controlled, which device provides that function, and how it will be accessed and commissioned.

Chicago TempShield demonstrates the integrated certified approach; Sloan and Zurn illustrate modular below-deck strategies; while Fontana and BathSelect show how commercial sensing and temperature control can be consolidated into more integrated fixture platforms.

Review Fontana Commercial Temperature Control Faucet →

Independent editorial disclosure: ArchFaucets.com provides independent architecture and specification-oriented analysis. Temperature-control requirements vary by code, application and jurisdiction. Verify the exact submitted device, certification, temperature range, flow requirements and current manufacturer technical data before approval.